Example combustion plants of type SICF-S
All information and sizes of plants are available as PDF download on our download page!
SCHLAMM- UND FESTSTOFFVERBRENNUNG
SLUDGE AND SOLID INCINERATION
(Non-binding)
Plant type | SICF 400-S | |
Combustion mass | 400 | [kg/h] |
Calorific value up to | 15000 | [kJ/kg] |
Main Chamber | ||
Temperature | 850 | [°C] |
Length (Outside) | 4600 | [mm] |
Width (Outside) | 2100 | [mm] |
Height (Outside) | 2600 | [mm] |
Burner MCC | ||
Installed burner rating min. | 1284 | [kW] |
Burner installed | 1 | [pcs] |
Burner series | monarch® Burner | |
Burner type | WM-L20/2-A Execution R | |
Performance range | 600 – 2100 (2600) | [kW] |
Weight MCC | ||
Steel | 3209 | [kg] |
Insulation and support wall SR | 13311 | [kg] |
Total weight MCC | 16520 | [kg] |
Afterburner chamber | ||
Temperature | 1100 | [°C] |
Length (Outside) | 4100 | [mm] |
Width (Outside) | 2100 | [mm] |
Height (Outside) | 2600 | [mm] |
Auxiliary burner SCC | ||
Installed burner rating min. | 550 | [kW] |
Burner installed | 1 | [pcs] |
Burner series | monarch® Burner | |
Burner type | WM-L20/2-A Execution R | |
Performance range | 600 – 2100 (2600) | [kW] |
Weight SCC | ||
Steel | 3211 | [kg] |
Insulation | 4254 | [kg] |
Total weight SCC | 7465 | [kg] |
Total weight MCC/SCC | 23985 | [kg] |
Flue gas | ||
Volume Operation | 15215 | [m³/h wet] |
Flue gas residence time min. | 2,5 | [s] |
Flue gas pipe | 559 | [mm] |
Induced draft fan | ||
Static pressure ρ= 0,75 kg/m³ | 5000 | [Pa] |
Volume flow rate | 21336 | [m³/h] |
Type | P-LRZ9B/500/800/1 | |
Fan Motor power | 55 | [kW] |
Combustion air | ||
Fan combustion air | ||
Static pressure ρ= 1,20 kg/m³ | 3150 | [Pa] |
Volume flow rate | 3381 | [m³/h] |
Type | A-MRZ10E/200/530/1 | |
Fan Motor power | 5,5 | [kW] |
ZANNI grate | ||
Grate size | 5,25 | [m²] |
ZANNI air/air cooler | Single system | [Type] |
Inlet temperature flue gas | 1100 | [°C] |
Cooling air inlet temperature | 40 | [°C] |
Mass flow flue gas in | 3903 | [kg/h] |
Volume flow cooling air in | 8128 | [m³/h] |
Fan cooling air | ||
Static pressure ρ= 1,12 kg/m³ | 5000 | [Pa] |
Volume flow rate | 9172 | [m³/h] |
Type | A-LRZ9B/400/630/1 | |
Fan Motor power | 18,5 | [kW] |
Fan mixed air chimney | ||
Static pressure ρ= 1,20 kg/m³ | 3150 | [Pa] |
Volume flow rate | 8586 | [m³/h] |
Type | A-RNZ9/400/500/1 | |
Fan Motor power | 11 | [kW] |
Cooling air duct | 508 | [mm] |
Flue gas pipe Out | 355,6 | [mm] |
Exhaust gas outlet temperature | 199,8 | [°C] |
Outlet temperature cooling air | 421,9 | [°C] |
Boiler/energy max. | ||
Boiler efficiency max. | 65 | [% Therm.] |
Steam output max. | 1461 | [kg/h] |
Power – Electrical max. | 351 | [kW/h Electr.] |
Flue gas filter | ||
Compressed air requirement | 6,3 | m³N DL/h |
Number of modules | 4 | [pcs] |
Side channel blower | ||
Pressure max. | 28000 | [Pa] |
Volume flow rate max. | 534 | [Nm³/h] |
Type | 2SD 820 – 50/8,50 | |
Fan Motor power | 8,50 | [kW] |
Chimneys | ||
Emergency chimney | 355,6 | [mm] |
Cooling air chimney | 508 | [mm] |
Flue gas chimney | 355,6 | [mm] |
Footprint overall | ||
Length A | 25,9 | m |
Width B | 25,2 | m |
Floor space | 652,7 | m² |
Footprint W2E | ||
Length C | 6,7 | m |
Width D | 4,5 | m |
Floor space | 30,2 | m² |
Hall combustion | ||
Length | 8,2 | m |
Width | 8,4 | m |
Floor space | 68,9 | m² |
Roofing of | MCC/SCC | |
Freestanding | A/A-C, FH, | |
Drawings | ||
Drawing numbers | 1860-400KG-SR10S-202020000952 | |
Note | © ZANNI GROUP | |
Drawing status | -REV-03 | |
Download Source | ||
Technical data sheet | ||
Version | 11/2020 | |
Download Source |
Subject to change.
Sample data only.
Changes to individual parameters can affect all values!
Overview of all SICF plants (200 - 1000 kg/h) - SICF 200 (200 kg/h) - SICF 300 (300 kg/h) - SICF 400 (400 kg/h) - SICF 500 (500 kg/h) - SICF 600 (600 kg/h) - SICF 800 (800 kg/h) - SICF 1000 (1000 kg/h)
Larger systems as individual solutions.