Menu above.
Explanations below.

Example combustion plants of type SICF-S

All information and sizes of plants are available as PDF download on our download page!

SCHLAMM- UND FESTSTOFFVERBRENNUNG
SLUDGE AND SOLID INCINERATION

(Non-binding)

Plant type

SICF 400-S


Combustion mass

400

[kg/h]

Calorific value up to

15000

[kJ/kg]

Main Chamber



Temperature

850

[°C]

Length (Outside)

4600

[mm]

Width (Outside)

2100

[mm]

Height (Outside)

2600

[mm]

Burner MCC



Installed burner rating min.

1284

[kW]

Burner installed

1

[pcs]

Burner series

monarch® Burner


Burner type

WM-L20/2-A Execution R


Performance range

600 – 2100 (2600)

[kW]

Weight MCC



Steel

3209

[kg]

Insulation and support wall SR

13311

[kg]

Total weight MCC

16520

[kg]

Afterburner chamber



Temperature

1100

[°C]

Length (Outside)

4100

[mm]

Width (Outside)

2100

[mm]

Height (Outside)

2600

[mm]

Auxiliary burner SCC



Installed burner rating min.

550

[kW]

Burner installed

1

[pcs]

Burner series

monarch® Burner


Burner type

WM-L20/2-A Execution R


Performance range

600 – 2100 (2600)

[kW]

Weight SCC



Steel

3211

[kg]

Insulation

4254

[kg]

Total weight SCC

7465

[kg]

Total weight MCC/SCC

23985

[kg]

Flue gas



Volume Operation

15215

[m³/h wet]

Flue gas residence time min.

2,5

[s]

Flue gas pipe

559

[mm]

Induced draft fan



Static pressure ρ= 0,75 kg/m³

5000

[Pa]

Volume flow rate

21336

[m³/h]

Type

P-LRZ9B/500/800/1


Fan Motor power

55

[kW]

Combustion air



Fan combustion air



Static pressure ρ= 1,20 kg/m³

3150

[Pa]

Volume flow rate

3381

[m³/h]

Type

A-MRZ10E/200/530/1


Fan Motor power

5,5

[kW]

ZANNI grate



Grate size

5,25

[m²]

ZANNI air/air cooler

Single system

[Type]

Inlet temperature flue gas

1100

[°C]

Cooling air inlet temperature

40

[°C]

Mass flow flue gas in

3903

[kg/h]

Volume flow cooling air in

8128

[m³/h]

Fan cooling air



Static pressure ρ= 1,12 kg/m³

5000

[Pa]

Volume flow rate

9172

[m³/h]

Type

A-LRZ9B/400/630/1


Fan Motor power

18,5

[kW]

Fan mixed air chimney



Static pressure ρ= 1,20 kg/m³

3150

[Pa]

Volume flow rate

8586

[m³/h]

Type

A-RNZ9/400/500/1


Fan Motor power

11

[kW]

Cooling air duct

508

[mm]

Flue gas pipe Out

355,6

[mm]

Exhaust gas outlet temperature

199,8

[°C]

Outlet temperature cooling air

421,9

[°C]

Boiler/energy max.



Boiler efficiency max.

65

[% Therm.]

Steam output max.

1461

[kg/h]

Power – Electrical max.

351

[kW/h Electr.]

Flue gas filter



Compressed air requirement

6,3

m³N DL/h

Number of modules

4

[pcs]

Side channel blower



Pressure max.

28000

[Pa]

Volume flow rate max.

534

[Nm³/h]

Type

2SD 820 – 50/8,50


Fan Motor power

8,50

[kW]

Chimneys



Emergency chimney

355,6

[mm]

Cooling air chimney

508

[mm]

Flue gas chimney

355,6

[mm]

Footprint overall



Length A

25,9

m

Width B

25,2

m

Floor space

652,7

Footprint W2E



Length C

6,7

m

Width D

4,5

m

Floor space

30,2

Hall combustion



Length

8,2

m

Width

8,4

m

Floor space

68,9

Roofing of

MCC/SCC


Freestanding

A/A-C, FH,
Others


Drawings



Drawing numbers

1860-400KG-SR10S-202020000952


Note

© ZANNI GROUP


Drawing status

-REV-03


Download Source

Download


Technical data sheet



Version

11/2020


Download Source

Download


Subject to change.

 Sample data only.
Changes to individual parameters can affect all values!

Overview of all SICF plants 
(200 - 1000 kg/h for sludges, up to 2000 kg/h for solid/mixed waste )

SICF 200 (200 kg/h)
SICF 300 (300 kg/h)
SICF 400 (400 kg/h)
SICF 500 (500 kg/h)
SICF 600 (600 kg/h)
SICF 800 (800 kg/h)
SICF 1000 (1000 kg/h)

 Larger systems as individual solutions.

E-Mail
Anruf
Karte
Infos
Instagram