Technical data

Combustion plants type SICF-S

SLUDGE AND SOLID INCINERATION

(Non-binding)

Plant type

SICF 200-S
SICF 400

SICF 300-S
SICF 600

SICF 400-S
SICF 800

SICF 500-S
SICF 1000

SICF 600-S
SICF 1200

SICF 800-S
SICF 1600

SICF 1000-S
SICF 2000


Combustion mass
Capacity up to

200 (sludge)
400 (solid waste)

300 (sludge)
600 (solid waste)

400 (sludge)
800 (solid waste)

500 (sludge)
1000 (solid waste)

600 (sludge)
1200 (solid waste)

800 (sludge)
1600 (solid waste)

1000 (sludge)
2000 (solid waste)

[kg/h]

Example data for combustion of

Sludge

Sludge

Sludge

Sludge

Sludge

Sludge

Sludge

Media

Calorific value up to

15000

15000

15000

15000

15000

15000

15000

[kJ/kg]

Main Chamber









Temperature

850

850

850

850

850

850

850

[°C]

Length (Outside)

3800

3800

4600

4800

5600

6900

7100

[mm]

Width (Outside)

2100

2100

2100

2100

2100

2100

2100

[mm]

Height (Outside)

2100

2100

2600

2700

2900

3200

3200

[mm]

Burner MCC









Installed burner rating min.

642

936

1284

1605

1927

2569

3211

[kW]

Burner installed

1

1

1

1

1

2

2

[pcs]

Burner series

monarch® Burner

monarch® Burner

monarch® Burner

monarch® Burner

monarch® Burner

monarch® Burner

monarch® Burner


Burner type

WM-L20/2-A Execution R

WM-L20/2-A Execution R

WM-L20/2-A Execution R

WM-L20/2-A Execution R

WM-L20/2-A Execution R

WM-L20/2-A Execution R

WM-L20/2-A Execution R


Performance range

600 – 2100 (2600)

600 – 2100 (2600)

600 – 2100 (2600)

600 – 2100 (2600)

600 – 2100 (2600)

600 – 2100 (2600)

600 – 2100 (2600)

[kW]

Weight MCC









Steel

2440

2440

3209

3396

4025

5095

5222

[kg]

Insulation and support wall SR

9774

9774

13311

14176

17020

21993

22569

[kg]

Total weight MCC

12214

12214

16520

17572

21045

27088

27791

[kg]

Afterburner chamber









Temperature

1100

1100

1100

1100

1100

1100

1100

[°C]

Length (Outside)

3400

3400

4100

4800

5600

7200

8600

[mm]

Width (Outside)

2100

2100

2100

2100

2100

2100

2100

[mm]

Height (Outside)

2100

2100

2600

2700

2900

3200

3200

[mm]

Auxiliary burner SCC









Installed burner rating min.

275

413

550

688

826

1101

1376 (2x688)

[kW]

Burner installed

1

1

1

1

1

1

1

[pcs]

Burner series

monarch® Burner

monarch® Burner

monarch® Burner

monarch® Burner

monarch® Burner

monarch® Burner

monarch® Burner


Burner type

WM-L20/2-A Execution R

WM-L20/2-A Execution R

WM-L20/2-A Execution R

WM-L20/2-A Execution R

WM-L20/2-A Execution R

WM-L20/2-A Execution R

WM-L20/2-A Execution R


Performance range

600 – 2100 (2600)

600 – 2100 (2600)

600 – 2100 (2600)

600 – 2100 (2600)

600 – 2100 (2600)

600 – 2100 (2600)

600 – 2100 (2600)

[kW]

Weight SCC









Steel

2465

2465

3211

3695

4346

5640

6530

[kg]

Insulation

3379

3379

4254

4932

5781

7472

8769

[kg]

Total weight SCC

5844

5844

7465

8628

10127

13112

15299

[kg]

Total weight MCC/SCC

18058

18058

23985

26200

31172

40200

43090

[kg]

Flue gas









Volume Operation

7607

11411

15215

19019

22822

30430

38037

[m³/h wet]

Flue gas residence time min.

2,5

2,5

2,5

2,5

2,5

2,5

2,5

[s]

Flue gas pipe

406

559

559

610

710

800

900

[mm]

Induced draft fan









Static pressure ρ= 0,75 kg/m³

5000

5000

5000

5000

5000

5000

5000

[Pa]

Volume flow rate

10753

17069

21336

27310

34137

42671

53766

[m³/h]

Type

P-PRZ9/355/800/1

P-LRZ9/450/710/1

P-LRZ9B/500/800/1

P-LRZ9C/560/800/1

P-RNZ9/630/800/1

P-RNZ9/710/900/1

P-RNZ9/800/1000/1 (d2 980)


Fan Motor power

30

45

55

75

90

110

132

[kW]

Combustion air









Fan combustion air









Static pressure ρ= 1,20 kg/m³

3150

3150

3150

3150

3150

3150

3150

[Pa]

Volume flow rate

1717

2683

3381

4293

5366

6761

8586

[m³/h]

Type

A-MRZ10B/160/500/1

A-MRZ10C/180/530/1

A-MRZ10E/200/530/1

A-MRZ10E/224/600/1

A-MRZ10/250/800/1

A-MRZ10A/280/850/1

A-MRZ10C/315/950/1


Fan Motor power

3

4

5,5

7,5

7,5

11

15

[kW]

ZANNI grate









Grate size

4,05

4,05

5,25

5,55

6,75

8,70

9,00

[m²]

ZANNI air/air cooler

Single system

Single system

Single system

Single system

Single system

Double system

Double system

[Type]

Inlet temperature flue gas

1100

1100

1100

1100

1100

1100

1100

[°C]

Cooling air inlet temperature

40

40

40

40

40

40

40

[°C]

Mass flow flue gas in

1952

2927

3903

4879

5855

7806

9758

[kg/h]

Volume flow cooling air in

3887

5919

8128

9718

11485

14135

18553

[m³/h]

Fan cooling air









Static pressure ρ= 1,12 kg/m³

5000

5000

5000

5000

5000

5000

5000

[Pa]

Volume flow rate

4586

7223

9172

11465

14331

14331

22929

[m³/h]

Type

A-PRZ9/250/560/1

A-LRZ9/355/560/1

A-LRZ9B/400/630/1

A-LRZ9C/450/630/1

A-RNZ9/500/630/1

A-RNZ9/500/630/1

A-RNZ9/560/710/1


Fan Motor power

11

15

18,5

30

30

30

45

[kW]

Fan mixed air chimney









Static pressure ρ= 1,20 kg/m³

3150

3150

3150

3150

3150

3150

3150

[Pa]

Volume flow rate

5366

6761

8586

12878

12878

21464

26830

[m³/h]

Type

A-LRZ9/315/500/1

A-LRZ9C/355/500/1

A-RNZ9/400/500/1

A-RNZ9/450/560/1

A-RNZ9/450/560/1

A-RNNS6/560/710/1

A-RNSK6/630/800/1


Fan Motor power

7,5

11

11

18,5

18,5

30

37

[kW]

Cooling air duct

508

508

508

559

610

630

710

[mm]

Flue gas pipe Out

355,6

355,6

355,6

355,6

406,4

457

508

[mm]

Exhaust gas outlet temperature

196,2

199,9

199,8

199,2

197,7

198,6

197,8

[°C]

Outlet temperature cooling air

440,9

433,3

421,9

439,5

446,4

479,8

459,2

[°C]

Boiler/energy max.









Boiler efficiency max.

65

65

65

65

65

65

65

[% Therm.]

Steam output max.

730

1096

1461

1826

2191

2922

3652

[kg/h]

Power – Electrical max.

175

263

351

438

526

701

877

[kW/h Electr.]

Flue gas filter









Compressed air requirement

3,1

4,7

6,3

7,8

9,4

12,5

15,6

m³N DL/h

Number of modules

2

3

4

5

6

8

8

[pcs]

Side channel blower









Pressure max.

20000

20000

28000

28000

29000

35000

35000

[Pa]

Volume flow rate max.

318

318

534

534

660

1050

1050

[Nm³/h]

Type

2SD 720 – 50/3,00

SD 80 – 50/5,50

2SD 820 – 50/8,50

SD 9 – 50/13,50

1SD 910 – 50/18,5

2SD 920 – 50/16,50

2SD 920 – 50/16,50


Fan Motor power

3,00

5,50

8,50

13,50

18,50

16,50

16,50

[kW]

Chimneys









Emergency chimney

355,6

355,6

355,6

355,6

406,4

457

508

[mm]

Cooling air chimney

508

508

508

559

610

630

710

[mm]

Flue gas chimney

355,6

355,6

355,6

355,6

406,4

457

508

[mm]

Footprint overall









Length A

25,3

25,3

25,9

29,0

29,0

33,2

36,5

m

Width B

20,8

20,8

25,2

25,2

25,7

25,0

26,4

m

Floor space

526,2

526,2

652,7

730,8

745,3

830,0

963,6

Footprint W2E









Length C

8,2

8,2

6,7

7,4

10,0

10,1

10,1

m

Width D

4,5

4,5

4,5

4,5

4,5

4,5

4,5

m

Floor space

36,9

36,9

30,2

33,3

45,0

45,5

45,5

Hall combustion









Length

7,2

7,2

8,2

9,8

9,8

11,1

12,1

m

Width

8,5

8,5

8,4

8,4

8,6

8,6

8,6

m

Floor space

61,2

61,2

68,9

82,3

84,3

95,5

104,1

Roofing of

MCC/SCC

MCC/SCC

MCC/SCC

MCC/SCC

MCC/SCC

MCC

MCC


Freestanding

A/A-C, FH,
Others

A/A-C, FH,
Others

A/A-C, FH,
Others

A/A-C, FH,
Others

A/A-C, FH,
Others

SCC, A/A-C, FH,
Others

SCC, A/A-C, FH,
Others


Drawings









Drawing numbers

1860-200KG-SR10S-202020000952

1860-300KG-SR10S-202020000952

1860-400KG-SR10S-202020000952

1860-600KG-SR10S-202020000952

1860-600KG-SR10S-202020000952

1860-800KG-SR10S-202020000952

1860-1000KG-SR10S-202020000952


Note

© ZANNI GROUP

© ZANNI GROUP

© ZANNI GROUP

© ZANNI GROUP | Equal design

© ZANNI GROUP

© ZANNI GROUP

© ZANNI GROUP


Drawing status

-REV-03

-REV-03

-REV-03

-REV-04

-REV-04

-REV-05

-REV-06


Technical data sheet









Version

11/2020

11/2020

11/2020

11/2020

11/2020

11/2020

11/2020



Subject to change.

 
 
 
E-Mail
Anruf
Karte
Infos
Instagram
LinkedIn